The dimensions and details on this page are specific to the Termate AM6 standoff insulator range.
For smaller sizes click here
Technical Data for AM6 standoff insulators
For smaller sizes click here
The below table shows the AM6 range of Termate standoff insulators.
The complete AM6 range is suitable for applications with an AC Equipment Voltage Ue up to 1000 V or DC Equipment Voltage Ue up to 1500 V.
The technical data provided in the table below provides information necessary for product selection and technical assessment in line with IEC and UL product standards.
We hold excellent stock of all of our products and will be happy to provide you a quotation for your requirements, please use our contact us page or email our customer support team.
Part number | 3D Model | Description | Height [H] (mm) | Thread Size* [M] | Thread Depth [D] (mm) | Maximum Tightening Torque (N·m) | Tensile Strength** (N) | Cantilever Strength** (N) | Box Qty. |
---|---|---|---|---|---|---|---|---|---|
AM6-060-08 | AM6-060-08 STEP file | 60mm high standoff insulator with M8 thread | 60 | M8 | 11 | 28 | 18100 | 8600 | 20 |
AM6-060-10 | AM6-060-10 STEP file | 60mm high standoff insulator with M10 thread | 60 | M10 | 16 | 55 | 24500 | 12600 | 20 |
AM6-060-10-12 | AM6-060-10-12 STEP file | 60mm high standoff insulator with an M10 and M12 thread either end | 60 | M10 + M12 | 16 | 55 | 24500 | 12600 | 20 |
AM6-060-12 | AM6-060-12 STEP file | 60mm high standoff insulator with M12 thread | 60 | M12 | 16 | 95 | 30300 | 17000 | 20 |
AM6-060-16 | AM6-060-16 STEP file | 60mm high standoff insulator with M16 thread | 60 | M16 | 22 | 130 | 41800 | 24500 | 20 |
AM6-070-08 | AM6-070-08 STEP file | 70mm high standoff insulator with M8 thread | 70 | M8 | 11 | 28 | 16900 | 7900 | 20 |
AM6-070-10 | AM6-070-10 STEP file | 70mm high standoff insulator with M10 thread | 70 | M10 | 16 | 55 | 23400 | 11300 | 20 |
AM6-070-12 | AM6-070-12 STEP file | 70mm high standoff insulator with M12 thread | 70 | M12 | 16 | 95 | 28300 | 14900 | 20 |
AM6-070-16 | AM6-070-16 STEP file | 70mm high standoff insulator with M16 thread | 70 | M16 | 22 | 130 | 31500 | 21400 | 20 |
AM6-100-08 | AM6-100-08 STEP file | 100mm high standoff insulator with M8 thread | 100 | M8 | 11 | 28 | 13500 | 5700 | 10 |
AM6-100-10 | AM6-100-10 STEP file | 100mm high standoff insulator with M10 thread | 100 | M10 | 16 | 55 | 20300 | 7300 | 10 |
AM6-100-12 | AM6-100-12 STEP file | 100mm high standoff insulator with M12 thread | 100 | M12 | 16 | 95 | 22200 | 8700 | 10 |
AM6-100-16 | AM6-100-16 STEP file | 100mm high standoff insulator with M16 thread | 100 | M16 | 22 | 130 | 35300 | 12400 | 10 |
* Fixing details: Hole diameter = Standoff thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter
** Tensile and Cantilever Strength figures are based on tests carried out at normal room temperature, nominal 23 °C.
Our Insulators have ISO M inserts with coarse threaded inserts in accordance with BS 3643-2 – Table 1 and ISO 262
Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.
The following tables shows the Recognition, Properties and Characteristics of the AM6 range of Termate standoff insulators.
Recognition | Reference / Link | Preferred name |
---|---|---|
UL Recognised Component | File Number: E505645 | |
EClass 8.0 | 27-08-10-08 | Insulator, plastic |
EClass 14.0 | 27-08-10-03 | Bus bar holder (insulator, post insulator) |
Properties | Value / Measure / Unit |
---|---|
Insulator Material | Glass Reinforced Polyamide 6.6 (PA66) |
Insert Material | Brass |
Operating Range in Celsius | This material operates in a wide temperature range: −40 °C to +130 °C |
Operating Range in Fahrenheit | This material operates in a wide temperature range: −40 °F to +266 °F |
Flammability | UL 94 V-0 |
Oxygen Index | 32% |
Glow Wire | 960 °C |
Characteristics | Value |
---|---|
Maximum Alternating Current Equipment Voltage, Ue | 1000 V |
Maximum Direct Current Equipment Voltage, Ue | 1500 V |
Impulse Voltage, Uimp | 12 kV |
The following table provides additional UL Yellow Card information, for the material used in AM6 standoff insulator range, required for assessing the suitability for incorporation into electrical equipment built to North American standards or for use when evaluating unlisted equipment for compliance with North American recognised standards, using methods such as NFPA 791.
Properties | Value | Test Method |
---|---|---|
Hot-wire Ignition (HWI) | PLC 0 | UL 746A |
High Amp Arc Ignition (HAI) | PLC 1 | UL 746A |
Comparative Tracking Index (CTI) | PLC 0 | UL 746A |
UV Exposure & Water Immersion | f1 | UL 746C |
Standoff Insulators:
The AM6 standoff insulator range provides excellent mechanical strength and electrical insulation, making it suitable for a wide range of application. Post insulators, egg insulators, bobbin insulators, and busbar isolators are also other names for standoff insulators.
Termate AM6 standoff insulators are available in thread sizes of M8 to M16, including heights ranging from 60 mm to 100 mm. The table above list the heights, thread depths and diameters, cantilever and tensile strengths, maximum tightening torques, and box quantities.
They also possess the following characteristics:
- Halogen Free
- Relative Thermal Index ranging from −40 °C to +130 °C
- Equipment voltage of up to 1000 V AC, 1500 V DC
- Insulation voltage of up to 1000 V AC, 1500 V DC
- Made from UL 94 V-0 rated, self-extinguishing material
- UL Recognised Component; file number E505645
Try our standoff insulator cross-reference tool.
Learn more about our AM1, AM2, and AM4 range of standoff insulators.
Standoff Insulator manufacture: :
Termate AM6 standoff insulators are made from a halogen-free glass-reinforced material with threaded brass inserts for better corrosion resistance.
The injection moulding method, which we utilise to make the bulk of our power distribution parts, including our standoff insulators, enhances overall product quality and allows for close dimensional tolerances.
Insulator Testing:
Product testing is critical for any component that will be used in an electrical or mechanical system.
Professional, thorough, and independent testing has been performed on the AM6 standoff insulator range to assure efficacy when installed correctly in their intended assembly.
Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.
One of the most widely used tests for determining the ability of plastic parts to self-extinguish after the heat source has been removed is UL 94. All Termate standoffs meet V-0 requirements for the UL 94 test standard.
Our standoff insulators have undergone comprehensive testing, including cantilever, torque, and tensile tests, to give you peace of mind that they will fulfil specified ratings when fitted appropriately.
The Applications of Standoff Insulators:
Any component that will be used in an electrical or mechanical system must be thoroughly tested. The AM6 standoff insulator has undergone extensive, rigorous, and independent testing to ensure functionality when installed correctly in its intended application.
Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.
UL 94 is one of the most widely employed methods of evaluating the flammability and self-extinguishing ability of plastic products.
The AM6 insulator range is manufactured from material meeting the UL 94 V-0 flammability rating for plastics.
Termate insulators have been thoroughly tested, including cantilever, torque, and tensile tests, to help ensure that they meet the specific ratings when installed correctly.
AM6 standoff insulators are designed to safely and securely support and insulate busbars and other active conductors by maintaining a space between two surfaces.
They are suitable for applications up to 1000 V AC and 1500 V DC. In these types of systems, the support’s electrical insulation and mechanical strength are crucial. The following are examples of common installations:
- Battery Energy Storage Systems
- Electrical panel boards
- Control panels
- Switchboards
- EV power trains
- Power factor correction
- Distribution boards
- Generators
- Switchgear
- Controlgear
- Drives, inverters and converters.
These electrical installations are utilised in a variety of industries, including power distribution, rail (rolling stock and trackside), UPS (temporary and emergency power), data centre power distribution, and renewable energy.
For more than 60 years, Termate has been expertly manufacturing specialised insulating products and components in Nottingham, UK.
We are committed to using our engineering knowledge to create and produce top-of-the-line parts, so you can be confident in the quality of our goods. For our customers, our in-house product development team is continually working to improve existing parts and develop new, unique components.
Termate is committed to the highest standard of customer focus and we have made every effort to maintain the accuracy and completeness of the information provided in this data. Where improvements to our products affect their installation and usage we endeavour to contact any customers who may be affected.
Warranty as stated in our Terms and Conditions of Trading is void if any modification is made to the warranted product.