Loading...

Termate’s Metric Range of standoff insulators provides dependable electrical insulation and mechanical strength across a wide variety of power and control applications.

Manufactured from halogen-free, UL 94 V-0 rated glass-reinforced polyamide 6.6, each insulator combines high rigidity, low smoke emission, and excellent resistance to heat and electrical stress.

The AM series covers everything from compact control panels and EV systems to large switchboards and energy storage installations, ensuring consistent performance across every scale of assembly.

With precision-moulded brass inserts and proven test results, the Metric Range delivers long-term reliability and safety in demanding electrical environments.

Need help specifying the right components?

AM1

20 – 35 mm
M5 or M6 thread

AM2

25 – 100 mm
M6, M8 or M10 thread

AM4

30 – 60 mm
M6, M8, M10 or M12 thread

AM6

60 – 100 mm
M8, M10, M12 or M16 thread

Need a bespoke solution?

Our compression & injection moulding expertise allows us to design & manufacture tailored components to your specification.

Key Features

  • UL Recognised Component
    (Files E505645 (US) and E505645 (CA))

  • AM1 Height range: 20–35 mm, Thread sizes: M5, M6
    AM2 Height range: 25–100 mm, Thread sizes: M6, M8
    AM4 Height range: 30–60 mm, Thread sizes: M6–M12
    AM6 Height range: 60–100 mm, Thread sizes: M8–M16

  • Material: Glass-reinforced polyamide 6.6 (halogen-free)
  • Insert material: Brass for corrosion resistance
  • Operating temperature: −40 °C to +130 °C (−40 °F to +266 °F)
  • Electrical rating: 1000 V AC / 1500 V DC, Impulse voltage: 12 kV
  • Flammability: UL 94 V-0, Glow wire: 960 °C
  • Oxygen Index: 32 %, CTI: 600 V
  • Low-smoke, self-extinguishing performance
  • Tested for tensile and cantilever strength at 23 °C
  • Convertible to Male/Male or Male/Female using Grub Screw Pack

Typical Applications

The AM range covers compact to heavy-duty insulators for industrial, rail, and renewable power systems.

Technical Information for Metric Range of Standoff Insulators

You will find useful technical information below but, if you have any questions, please contact our technical team for support.

All Metric Standoff Insulators

The table below lists the available sizes of the Metric Termate Standoff Insulator range.

These are provided with Metric Coarse threaded inserts moulded into the body.

Diagram showing the location of dimensions on the standoff insulator
FootprintHeight [H] | Thread Size [M]Width across flats [W] mmWidth across corners [X] mm
AM1From 20mm to 35mm with M5 or M6 threads1820
AM2From 25mm to 100mm with M6 or M8 threads2527
AM4From 30mm to 60mm with M6, M8 or M10 threads3538
AM6From 60mm to 100mm with M8, M10, M12 or M16 threads6065

Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.

AM1

The below table shows the AM1 range of Termate standoff insulators.

The complete AM1 range is suitable for applications with an AC Equipment Voltage Ue up to 1000 V or DC Equipment Voltage Ue up to 1500 V.

The technical data provided in the table below provides information necessary for product selection and technical assessment in line with IEC and UL product standards.

We hold excellent stock of all of our products and will be happy to provide you a quotation for your requirements, please use our contact us page or email our customer support team.

Part Number3D ModelDescriptionHeight
[H] (mm)
Thread Size*
[M]
Thread Depth
[D] (mm)
Maximum
Tightening Torque
(N·m)
Tensile Strength**
(N)
Cantilever Strength**
(N)
Box Qty.
AM1-020-05AM1-020-05 STEP file20mm high standoff insulator with M5 thread20M55442002350200
AM1-020-06AM1-020-06 STEP file20mm high standoff insulator with M6 thread20M67842002350200
AM1-025-05AM1-025-05 STEP file25mm high standoff insulator with M5 thread25M55442002350200
AM1-025-06AM1-025-06 STEP file25mm high standoff insulator with M6 thread25M67842002350200
AM1-030-05AM1-030-05 STEP file30mm high standoff insulator with M5 thread30M55442002350200
AM1-030-06AM1-030-06 STEP file30mm high standoff insulator with M6 thread30M67842002350200
AM1-035-05AM1-035-05 STEP file35mm high standoff insulator with M5 thread35M55442002350200
AM1-035-06AM1-035-06 STEP file35mm high standoff insulator with M6 thread35M67842002350200

* Fixing details: Hole diameter = Standoff thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter.

** Tensile and Cantilever Strength figures are based on tests carried out at normal room temperature, nominal 23 °C.

Our Insulators have ISO M inserts with coarse threaded inserts in accordance with BS 3643-2 – Table 1 and ISO 262.

Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.

RecognitionReference / LinkPreferred Name
UL US Recognised ComponentUS Certificate: UL-US-E505645
UL CA Recognised ComponentCA Certificate: UL-CA-E505645
EClass 8.027-08-10-08Insulator, plastic
EClass 14.027-08-10-03Bus bar holder (insulator, post insulator)
PropertiesValue / Measure / Unit
Insulator MaterialGlass Reinforced Polyamide 6.6 (PA66)
Insert MaterialBrass
Operating Range in Celsius−40 °C to +130 °C
Operating Range in Fahrenheit−40 °F to +266 °F
FlammabilityUL 94 V-0
Oxygen Index32%
Glow Wire960 °C
CharacteristicsValue
Maximum Alternating Current Equipment Voltage,
Ue
1000 V
Maximum Direct Current Equipment Voltage,
Ue
1500 V
Impulse Voltage,
Uimp
12 kV

The following table provides additional UL Yellow Card information, for the material used in AM1 standoff insulator range, required for assessing the suitability for incorporation into electrical equipment built to North American standards or for use when evaluating unlisted equipment for compliance with North American recognised standards, using methods such as NFPA 791.

PropertiesValueTest Method
Hot-wire Ignition (HWI)PLC 0UL 746A
High Amp Arc Ignition (HAI)PLC 1UL 746A
Comparative Tracking Index (CTI)PLC 0UL 746A
UV Exposure & Water Immersionf1UL 746C

Termate’s AM1 standoff insulator range provides excellent electrical insulation and mechanical strength for a variety of applications. Compact standoff insulators can also be referred to as pillar insulators, insulating posts, bobbin insulators, or busbar isolators.

This standoff insulator range is available in heights from 20 mm to 35 mm and insert sizes of M5 and M6. Technical data is found on the table above which displays heights, thread size and depth, maximum tightening torques, tensile and cantilever strengths, and box quantities available.

  • Made from UL 94 V-0 rated, self-extinguishing material
  • Halogen Free
  • Operating temperature range of −40 °C to +130 °C (−40 °F to +266 °F)
  • Insulation voltage of up to 1000 V AC, 1500 V DC
  • Equipment voltage of up to 1000 V AC, 1500 V DC

Our standoff insulators are made from a halogen-free glass-reinforced material, which was specifically chosen for its mechanical and electrical insulation properties.

Brass inserts are used due to this alloy’s resistance to corrosion. The injection moulding process, combined with our excellent quality control and inspection procedures, results in a consistent product across every production run.

The AM1 range of standoff insulators is an important product in the Termate catalogue. Prior to entering production, the insulators were subjected to a comprehensive suite of tests that examined their electrical and mechanical performance capabilities.

All tests were conducted within industry standards and with strict quality control measures enforced throughout. This rigorous testing procedure ensures our products are always performing optimally, providing customers with reliable and high-quality insulation solutions. We take pride in providing our customers with the highest quality of products, ensuring all safety and performance requirements are met.

AM1 standoff insulators are manufactured from material that meets the requirements for UL 94 V-0. UL 94 being a standard for the safety of flammability of plastic materials for parts in devices and appliances released by the Underwriters Laboratories.

Our complete Standoff insulator range are UL Recognised Components, more information can be found at UL Product.

Our standoff insulators are suitable for assemblies up to 1000 V AC or up to 1500 V DC. These insulation supports provide a solution for electrical systems that need the assurance of safe and secure insulation.

In installations which require electrical isolation, they ensure that distance is maintained between two surfaces. This maintains the required level of mechanical strength and electrical insulation needed to safely contain live conductors, such as busbars.

Usual installations are within:

  • Battery Energy Storage Systems
  • Electrical panel boards
  • Control panels
  • Switchboards
  • EV power trains
  • Power factor correction
  • Distribution boards
  • Drives, inverters and converters

These electrical installations can be found in a wide range of sectors including power distribution, rail (rolling stock & trackside), renewable energy, UPS (temporary and emergency power), and data centre power distribution.

AM2

The below table shows the AM2 range of Termate standoff insulators.

The complete AM2 range is suitable for applications with an AC Equipment Voltage Ue up to 1000 V or DC Equipment Voltage Ue up to 1500 V.

The technical data provided in the table below provides information necessary for product selection and technical assessment in line with IEC and UL product standards.

We hold excellent stock of all of our products and will be happy to provide you a quotation for your requirements, please use our contact us page or email our customer support team.

Plan and side view diagrams of the Termate standoff insulators in the AM2 footprint. Labels show width across flats is 25mm, width across corners is 27mm, base diameter is 22mm, and shoulder height is 6mm. Other dimensions are labelled with a letter, indicating a specific measurement in the table below.
Part Number3D ModelDescriptionHeight
[H] (mm)
Thread Size*
[M]
Thread Depth
[D] (mm)
Maximum
Tightening Torque
(N·m)
Tensile Strength**
(N)
Cantilever Strength**
(N)
Box Qty.
AM2-025-06AM2-025-06 STEP file25mm high standoff insulator with M6 thread25M671195005500120
AM2-030-06AM2-030-06 STEP file30mm high standoff insulator with M6 thread30M671195005200120
AM2-030-08AM2-030-08 STEP file30mm high standoff insulator with M8 thread30M8928125007300120
AM2-035-06AM2-035-06 STEP file35mm high standoff insulator with M6 thread35M671195004900120
AM2-035-08AM2-035-08 STEP file35mm high standoff insulator with M8 thread35M8928128006900120
AM2-040-06AM2-040-06 STEP file40mm high standoff insulator with M6 thread40M67119500470060
AM2-040-08AM2-040-08 STEP file40mm high standoff insulator with M8 thread40M8112813000660060
AM2-050-06AM2-050-06 STEP file50mm high standoff insulator with M6 thread50M67119600410060
AM2-050-08AM2-050-08 STEP file50mm high standoff insulator with M8 thread50M8112813600580060
AM2-060-06AM2-060-06 STEP file60mm high standoff insulator with M6 thread60M67119700360050
AM2-060-08AM2-060-08 STEP file60mm high standoff insulator with M8 thread60M8112814100510050
AM2-080-06AM2-080-06 STEP file80mm high standoff insulator with M6 thread80M67119800250040
AM2-080-08AM2-080-08 STEP file80mm high standoff insulator with M8 thread80M8112815100360040
AM2-100-06AM2-100-06 STEP file100mm high standoff insulator with M6 thread100M67119900140030
AM2-100-08AM2-100-08 STEP file100mm high standoff insulator with M8 thread100M8112816100220030

* Fixing details: Hole diameter = Standoff thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter.

** Tensile and Cantilever Strength figures are based on tests carried out at normal room temperature, nominal 23 °C.

Our Insulators have ISO M inserts with coarse threaded inserts in accordance with BS 3643-2 – Table 1 and ISO 262

Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.

RecognitionReference / LinkPreferred Name
UL US Recognised ComponentUS Certificate: UL-US-E505645
UL CA Recognised ComponentCA Certificate: UL-CA-E505645
EClass 8.027-08-10-08Insulator, plastic
EClass 14.027-08-10-03Bus bar holder (insulator, post insulator)
PropertiesValue / Measure / Unit
Insulator MaterialGlass Reinforced Polyamide 6.6 (PA66)
Insert MaterialBrass
Operating Range in Celsius−40 °C to +130 °C
Operating Range in Fahrenheit−40 °F to +266 °F
FlammabilityUL 94 V-0
Oxygen Index32%
Glow Wire960 °C
CharacteristicsValue
Maximum Alternating Current Equipment Voltage,
Ue
1000 V
Maximum Direct Current Equipment Voltage,
Ue
1500 V
Impulse Voltage,
Uimp
12 kV

The following table provides additional UL Yellow Card information, for the material used in AM2 standoff insulator range, required for assessing the suitability for incorporation into electrical equipment built to North American standards or for use when evaluating unlisted equipment for compliance with North American recognised standards, using methods such as NFPA 791.

PropertiesValueTest Method
Hot-wire Ignition (HWI)PLC 0UL 746A
High Amp Arc Ignition (HAI)PLC 1UL 746A
Comparative Tracking Index (CTI)PLC 0UL 746A
UV Exposure & Water Immersionf1UL 746C

Termate’s AM2 standoff insulator range provides excellent electrical insulation and mechanical strength for a variety of applications. Standoff insulators can also be referred to as post insulators, egg insulators, bobbin insulators, or busbar isolators.

This standoff insulator range is available in heights from 25 mm to 100 mm and insert sizes of M6 and M8. Technical data is found on the table above which displays heights, thread size and depth, maximum tightening torques, tensile and cantilever strengths, and box quantities available.

  • Made from UL 94 V-0 rated, self-extinguishing material
  • Halogen Free
  • Operating temperature range of −40 °C to +130 °C
  • Insulation voltage of up to 1000 V AC, 1500 V DC
  • Equipment voltage of up to 1000 V AC, 1500 V DC
  • UL Recognised Component; file number E505645

Our standoff insulators are made from a halogen-free glass-reinforced material, which was specifically chosen for its mechanical and electrical insulation properties.

Brass inserts are used due to this alloy’s resistance to corrosion. The injection moulding process, combined with our excellent quality control and inspection procedures, results in a consistent product across every production run.

Termate can carry out rigorous and appropriate testing of your products or we can perform testing on our own products as required.

The AM2 range of standoff insulators have undergone extensive testing to ensure their electrical and mechanical capabilities.

AM2 standoff insulators meet the requirements for UL 94 V-0. UL 94 being a standard for the safety of flammability of plastic materials for parts in devices and appliances released by the Underwriters Laboratories.

The insulating stand off range is also fully compliant with the applicable clauses within the international standard for low-voltage switchgear and controlgear assemblies, IEC 61439.

Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.

Our standoff insulators are suitable for assemblies up to 1000 V AC or up to 1500 V DC. They are intended to safely and securely support and insulate busbars and other live conductors by maintaining a distance between two surfaces. In these types of installations, the electrical insulation and the mechanical strength of the support are paramount. Usual installations are within:

  • Battery Energy Storage Systems
  • Electrical panel boards
  • Control panels
  • Switchboards
  • EV power trains
  • Power factor correction
  • Distribution boards
  • Generators
  • Switchgear
  • Controlgear
  • Drives, inverters and converters

These electrical installations can be found in a wide range of sectors including power distribution, rail (rolling stock & trackside), renewable energy, UPS (temporary and emergency power), and data centre power distribution.

At Termate, we have been designing and manufacturing electrical insulating parts and components, such as our standoff insulators, from our Nottingham UK based factory for over 60 years. Quality is ensured on every product we produce. Our knowledge and experience of the raw materials used, the performance requirements, and the application of our products allow us to provide products that are safe and fit for purpose.

AM4

The below table shows the AM4 range of Termate standoff insulators.

The complete AM4 range is suitable for applications with an AC Equipment Voltage Ue up to 1000 V or DC Equipment Voltage Ue up to 1500 V.

The technical data provided in the table below provides information necessary for product selection and technical assessment in line with IEC and UL product standards.

We hold excellent stock of all of our products and will be happy to provide you a quotation for your requirements, please use our contact us page or email our customer support team.

Diagramas de vista en planta y lateral de los aisladores de separación imperial Termate en la huella AM4. Las etiquetas muestran las dimensiones específicas de la anchura entre planos, la anchura entre esquinas, el diámetro de la base y la altura del hombro. La altura, el tamaño del inserto y la profundidad de la rosca se indican mediante letras que se relacionan con dimensiones específicas en la tabla siguiente.
Part Number3D ModelDescriptionHeight
[H] (mm)
Thread Size*
[M]
Thread Depth
[D] (mm)
Maximum
Tightening Torque
(N·m)
Tensile Strength**
(N)
Cantilever Strength**
(N)
Box Qty.
AM4-030-06AM4-030-06 STEP file30mm high standoff insulator with M6 thread30M671112300640060
AM4-030-08AM4-030-08 STEP file30mm high standoff insulator with M8 thread30M892815500930060
AM4-035-06AM4-035-06 STEP file35mm high standoff insulator with M6 thread35M671112300600060
AM4-035-08AM4-035-08 STEP file35mm high standoff insulator with M8 thread35M892815900880060
AM4-035-10AM4-035-10 STEP file35mm high standoff insulator with M10 thread35M101055190001240060
AM4-040-06AM4-040-06 STEP file40mm high standoff insulator with M6 thread40M671112200550050
AM4-040-08AM4-040-08 STEP file40mm high standoff insulator with M8 thread40M8112816300840050
AM4-040-10AM4-040-10 STEP file40mm high standoff insulator with M10 thread40M101055195001180050
AM4-045-06AM4-045-06 STEP file45mm high standoff insulator with M6 thread45M671112200500050
AM4-045-08AM4-045-08 STEP file45mm high standoff insulator with M8 thread45M8112816700790050
AM4-045-10AM4-045-10 STEP file45mm high standoff insulator with M10 thread45M101655200001120050
AM4-050-06AM4-050-06 STEP file50mm high standoff insulator with M6 thread50M671112200460025
AM4-050-08AM4-050-08 STEP file50mm high standoff insulator with M8 thread50M8112817100740025
AM4-050-10AM4-050-10 STEP file50mm high standoff insulator with M10 thread50M101655205001060025
AM4-050-12AM4-050-12 STEP file50mm high standoff insulator with M12 thread50M121695266001400025
AM4-060-08AM4-060-08 STEP file60mm high standoff insulator with M8 thread60M8112817900650025
AM4-060-10AM4-060-10 STEP file60mm high standoff insulator with M10 thread60M10165521400950025
AM4-060-12AM4-060-12 STEP file60mm high standoff insulator with M12 thread60M121695271001140025

* Fixing details: Hole diameter = Standoff thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter

** Tensile and Cantilever Strength figures are based on tests carried out at normal room temperature, nominal 23 °C

Our Insulators have ISO M inserts with coarse threaded inserts in accordance with BS 3643-2 – Table 1 and ISO 262

Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.

RecognitionReference / LinkPreferred name
UL US Recognised ComponentUS Certificate: UL-US-E505645
UL CA Recognised ComponentCA Certificate: UL-CA-E505645
EClass 8.027-08-10-08Insulator, plastic
EClass 14.027-08-10-03Bus bar holder (insulator, post insulator)
PropertiesValue / Measure / Unit
Insulator MaterialGlass Reinforced Polyamide 6.6 (PA66)
Insert MaterialBrass
Operating Range in CelsiusThis material operates in a wide temperature range: −40 °C to +130 °C
Operating Range in FahrenheitThis material operates in a wide temperature range: −40 °F to +266 °F
FlammabilityUL 94 V-0
Oxygen Index32%
Glow Wire960 °C
CharacteristicsValue
Maximum Alternating Current Equipment Voltage,
Ue
1000 V
Maximum Direct Current Equipment Voltage,
Ue
1500 V
Impulse Voltage,
Uimp
12 kV

The following table provides additional UL Yellow Card information, for the material used in AM4 standoff insulator range, required for assessing the suitability for incorporation into electrical equipment built to North American standards or for use when evaluating unlisted equipment for compliance with North American recognised standards, using methods such as NFPA 791.

PropertiesValueTest Method
Hot-wire Ignition (HWI)PLC 0UL 746A
High Amp Arc Ignition (HAI)PLC 1UL 746A
Comparative Tracking Index (CTI)PLC 0UL 746A
UV Exposure & Water Immersionf1UL 746C

Suitable for a variety of assemblies, the AM4 standoff insulator range supplies excellent mechanical strength and electrical insulation.

Post insulators, egg insulators, bobbin insulators, and busbar isolators are all terms used to describe standoff insulators.

Our AM4 insulating standoffs come in different heights from 30 mm to 60 mm, as well as insert sizes of M6 to M12. Heights, thread depths and sizes, maximum tightening torques, cantilever and tensile strengths, and box quantities are all listed in the table above.

The AM4 insulators have the following properties:

  • Halogen Free
  • Equipment voltage of up to 1000 V AC, 1500 V DC
  • Insulation voltage of up to 1000 V AC, 1500 V DC
  • Operating temperature ranging from −40 °C to +130 °C
  • UL Recognised Component; file number E505645
  • Made from UL 94 V-0 rated, self-extinguishing material

Termate AM4 standoff insulators are manufactured from halogen free glass-reinforced polyamide 6.6 material and contain precision threaded brass alloy inserts for greater corrosion resistance.

The injection moulding process we use to manufacture our electrical insulating parts improves overall product quality and design accuracy.

Product testing is critical for any component that will be used in an electrical or mechanical system.

Professional, thorough, and independent testing has been performed on the AM4 standoff insulator range to assure efficacy when installed correctly in their intended assembly.

Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.

One of the most widely used tests for determining the ability of plastic parts to self-extinguish after the heat source has been removed is UL 94. All Termate standoffs meet V-0 requirements for the UL 94 test standard.

Our standoff insulators have undergone comprehensive testing, including cantilever, torque, and tensile tests, to give you peace of mind that they will fulfil specified ratings when fitted appropriately.

These standoff insulators are designed to hold live busbars and other active conductors as an insulating support, safely and securely, by keeping a gap between two surfaces and is appropriate for assemblies up to 1000 V AC & 1500 V DC.

The electrical insulation and mechanical strength of the support are critical in these types of systems.

A list of some of the most common applications for our insulators include:

  • Battery Energy Storage Systems
  • Electrical panel boards
  • Control panels
  • Switchboards
  • EV power trains
  • Power factor correction
  • Distribution boards
  • Generators
  • Switchgear
  • Controlgear
  • Drives, inverters and converters

Power distribution, rail (rolling stock & trackside), renewable energy, UPS (temporary and emergency power), and data centre power distribution are all examples of sectors where these electrical installations and assemblies are used.

For over 60 years, Termate has designed and manufactured electrical insulating parts and components at our UK-based site. Every insulating plastic product we make is of the highest quality so that we can provide electrical insulating solutions that are safe and suitable for purpose. By becoming a part of our portfolio of trusted customers, we can provide time-effective results for your projects.

AM6

The below table shows the AM6 range of Termate standoff insulators.

The complete AM6 range is suitable for applications with an AC Equipment Voltage Ue up to 1000 V or DC Equipment Voltage Ue up to 1500 V.

The technical data provided in the table below provides information necessary for product selection and technical assessment in line with IEC and UL product standards.

We hold excellent stock of all of our products and will be happy to provide you a quotation for your requirements, please use our contact us page or email our customer support team.

Plan and side view diagrams of the Termate standoff insulators in the AU6 footprint. Labels show width across flats is 60mm, width across corners is 65mm, base diameter is 53mm, and shoulder height is 22.5mm. Other dimensions are labelled with a letter, indicating a specific measurement in the table below.
Part Number3D ModelDescriptionHeight
[H] (mm)
Thread Size*
[M]
Thread Depth
[D] (mm)
Maximum
Tightening Torque
(N·m)
Tensile Strength**
(N)
Cantilever Strength**
(N)
Box Qty.
AM6-060-08AM6-060-08 STEP file60mm high standoff insulator with M8 thread60M8112818100860020
AM6-060-10AM6-060-10 STEP file60mm high standoff insulator with M10 thread60M101655245001260020
AM6-060-10-12AM6-060-10-12 STEP file60mm high standoff insulator with an M10 and M12 thread either end60M10 + M121655245001260020
AM6-060-12AM6-060-12 STEP file60mm high standoff insulator with M12 thread60M121695303001700020
AM6-060-16AM6-060-16 STEP file60mm high standoff insulator with M16 thread60M1622130418002450020
AM6-070-08AM6-070-08 STEP file70mm high standoff insulator with M8 thread70M8112816900790020
AM6-070-10AM6-070-10 STEP file70mm high standoff insulator with M10 thread70M101655234001130020
AM6-070-12AM6-070-12 STEP file70mm high standoff insulator with M12 thread70M121695283001490020
AM6-070-16AM6-070-16 STEP file70mm high standoff insulator with M16 thread70M1622130315002140020
AM6-100-08AM6-100-08 STEP file100mm high standoff insulator with M8 thread100M8112813500570010
AM6-100-10AM6-100-10 STEP file100mm high standoff insulator with M10 thread100M10165520300730010
AM6-100-12AM6-100-12 STEP file100mm high standoff insulator with M12 thread100M12169522200870010
AM6-100-16AM6-100-16 STEP file100mm high standoff insulator with M16 thread100M1622130353001240010

* Fixing details: Hole diameter = Standoff thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter

** Tensile and Cantilever Strength figures are based on tests carried out at normal room temperature, nominal 23 °C.

Our Insulators have ISO M inserts with coarse threaded inserts in accordance with BS 3643-2 – Table 1 and ISO 262

Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.

RecognitionReference / LinkPreferred name
UL US Recognised ComponentUS Certificate: UL-US-E505645
UL CA Recognised ComponentCA Certificate: UL-CA-E505645
EClass 8.027-08-10-08Insulator, plastic
EClass 14.027-08-10-03Bus bar holder (insulator, post insulator)
PropertiesValue / Measure / Unit
Insulator MaterialGlass Reinforced Polyamide 6.6 (PA66)
Insert MaterialBrass
Operating Range in CelsiusThis material operates in a wide temperature range: −40 °C to +130 °C
Operating Range in FahrenheitThis material operates in a wide temperature range: −40 °F to +266 °F
FlammabilityUL 94 V-0
Oxygen Index32%
Glow Wire960 °C
CharacteristicsValue
Maximum Alternating Current Equipment Voltage,
Ue
1000 V
Maximum Direct Current Equipment Voltage,
Ue
1500 V
Impulse Voltage,
Uimp
12 kV

The following table provides additional UL Yellow Card information, for the material used in AM6 standoff insulator range, required for assessing the suitability for incorporation into electrical equipment built to North American standards or for use when evaluating unlisted equipment for compliance with North American recognised standards, using methods such as NFPA 791.

PropertiesValueTest Method
Hot-wire Ignition (HWI)PLC 0UL 746A
High Amp Arc Ignition (HAI)PLC 1UL 746A
Comparative Tracking Index (CTI)PLC 0UL 746A
UV Exposure & Water Immersionf1UL 746C

The AM6 standoff insulator range provides excellent mechanical strength and electrical insulation, making it suitable for a wide range of application. Post insulators, egg insulators, bobbin insulators, and busbar isolators are also other names for standoff insulators.

Termate AM6 standoff insulators are available in thread sizes of M8 to M16, including heights ranging from 60 mm to 100 mm. The table above list the heights, thread depths and diameters, cantilever and tensile strengths, maximum tightening torques, and box quantities.

They also possess the following characteristics:

  • Halogen Free
  • Relative Thermal Index ranging from −40 °C to +130 °C
  • Equipment voltage of up to 1000 V AC, 1500 V DC
  • Insulation voltage of up to 1000 V AC, 1500 V DC
  • Made from UL 94 V-0 rated, self-extinguishing material
  • UL Recognised Component; file number E505645

Termate AM6 standoff insulators are made from a halogen-free glass-reinforced material with threaded brass inserts for better corrosion resistance.

The injection moulding method, which we utilise to make the bulk of our power distribution parts, including our standoff insulators, enhances overall product quality and allows for close dimensional tolerances.

Product testing is critical for any component that will be used in an electrical or mechanical system.

Professional, thorough, and independent testing has been performed on the AM6 standoff insulator range to assure efficacy when installed correctly in their intended assembly.

Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.

One of the most widely used tests for determining the ability of plastic parts to self-extinguish after the heat source has been removed is UL 94. All Termate standoffs meet V-0 requirements for the UL 94 test standard.

Our standoff insulators have undergone comprehensive testing, including cantilever, torque, and tensile tests, to give you peace of mind that they will fulfil specified ratings when fitted appropriately.

Any component that will be used in an electrical or mechanical system must be thoroughly tested. The AM6 standoff insulator has undergone extensive, rigorous, and independent testing to ensure functionality when installed correctly in its intended application.

Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.

UL 94 is one of the most widely employed methods of evaluating the flammability and self-extinguishing ability of plastic products.

The AM6 insulator range is manufactured from material meeting the UL 94 V-0 flammability rating for plastics.

Termate insulators have been thoroughly tested, including cantilever, torque, and tensile tests, to help ensure that they meet the specific ratings when installed correctly.

AM6 standoff insulators are designed to safely and securely support and insulate busbars and other active conductors by maintaining a space between two surfaces.

They are suitable for applications up to 1000 V AC and 1500 V DC. In these types of systems, the support’s electrical insulation and mechanical strength are crucial. The following are examples of common installations:

  • Battery Energy Storage Systems
  • Electrical panel boards
  • Control panels
  • Switchboards
  • EV power trains
  • Power factor correction
  • Distribution boards
  • Generators
  • Switchgear
  • Controlgear
  • Drives, inverters and converters.

These electrical installations are utilised in a variety of industries, including power distribution, rail (rolling stock and trackside), UPS (temporary and emergency power), data centre power distribution, and renewable energy.

For more than 60 years, Termate has been expertly manufacturing specialised insulating products and components in Nottingham, UK.

We are committed to using our engineering knowledge to create and produce top-of-the-line parts, so you can be confident in the quality of our goods. For our customers, our in-house product development team is continually working to improve existing parts and develop new, unique components.

Termate is committed to the highest standard of customer focus and we have made every effort to maintain the accuracy and completeness of the information provided in this data.

Where improvements to our products affect their installation and usage we endeavour to contact any customers who may be affected.

Warranty as stated in our Terms and Conditions of Trading is void if any modification is made to the warranted product.

Contact Us Today