Metric Range of Standoff Insulators
Reliable insulation for all industrial and power applications
Termate’s Metric Range of standoff insulators provides dependable electrical insulation and mechanical strength across a wide variety of power and control applications.
Manufactured from halogen-free, UL 94 V-0 rated glass-reinforced polyamide 6.6, each insulator combines high rigidity, low smoke emission, and excellent resistance to heat and electrical stress.
The AM series covers everything from compact control panels and EV systems to large switchboards and energy storage installations, ensuring consistent performance across every scale of assembly.
With precision-moulded brass inserts and proven test results, the Metric Range delivers long-term reliability and safety in demanding electrical environments.

Need help specifying the right components?
Need a bespoke solution?
Our compression & injection moulding expertise allows us to design & manufacture tailored components to your specification.

Key Features
UL Recognised Component
(Files E505645 (US) and E505645 (CA))AM1 Height range: 20–35 mm, Thread sizes: M5, M6
AM2 Height range: 25–100 mm, Thread sizes: M6, M8
AM4 Height range: 30–60 mm, Thread sizes: M6–M12
AM6 Height range: 60–100 mm, Thread sizes: M8–M16- Material: Glass-reinforced polyamide 6.6 (halogen-free)
- Insert material: Brass for corrosion resistance
- Operating temperature: −40 °C to +130 °C (−40 °F to +266 °F)
- Electrical rating: 1000 V AC / 1500 V DC, Impulse voltage: 12 kV
- Flammability: UL 94 V-0, Glow wire: 960 °C
- Oxygen Index: 32 %, CTI: 600 V
- Low-smoke, self-extinguishing performance
- Tested for tensile and cantilever strength at 23 °C
- Convertible to Male/Male or Male/Female using Grub Screw Pack
Typical Applications
The AM range covers compact to heavy-duty insulators for industrial, rail, and renewable power systems.
AM1 – Compact insulation for confined electrical assemblies
Click here to read more >>AM2 – Versatile support for medium-duty control systems
Click here to read more >>AM4 – Robust insulation for switchgear and energy networks
Click here to read more >>AM6 – High-strength insulation for large-scale power systems
Click here to read more >>

Technical Information for Metric Range of Standoff Insulators
You will find useful technical information below but, if you have any questions, please contact our technical team for support.
All Metric Standoff Insulators
The table below lists the available sizes of the Metric Termate Standoff Insulator range.
These are provided with Metric Coarse threaded inserts moulded into the body.

| Footprint | Height [H] | Thread Size [M] | Width across flats [W] mm | Width across corners [X] mm |
|---|---|---|---|
| AM1 | From 20mm to 35mm with M5 or M6 threads | 18 | 20 |
| AM2 | From 25mm to 100mm with M6 or M8 threads | 25 | 27 |
| AM4 | From 30mm to 60mm with M6, M8 or M10 threads | 35 | 38 |
| AM6 | From 60mm to 100mm with M8, M10, M12 or M16 threads | 60 | 65 |
Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.
AM1
The below table shows the AM1 range of Termate standoff insulators.
The complete AM1 range is suitable for applications with an AC Equipment Voltage Ue up to 1000 V or DC Equipment Voltage Ue up to 1500 V.
The technical data provided in the table below provides information necessary for product selection and technical assessment in line with IEC and UL product standards.
We hold excellent stock of all of our products and will be happy to provide you a quotation for your requirements, please use our contact us page or email our customer support team.

| Part Number | 3D Model | Description | Height [H] (mm) | Thread Size* [M] | Thread Depth [D] (mm) | Maximum Tightening Torque (N·m) | Tensile Strength** (N) | Cantilever Strength** (N) | Box Qty. |
|---|---|---|---|---|---|---|---|---|---|
| AM1-020-05 | AM1-020-05 STEP file | 20mm high standoff insulator with M5 thread | 20 | M5 | 5 | 4 | 4200 | 2350 | 200 |
| AM1-020-06 | AM1-020-06 STEP file | 20mm high standoff insulator with M6 thread | 20 | M6 | 7 | 8 | 4200 | 2350 | 200 |
| AM1-025-05 | AM1-025-05 STEP file | 25mm high standoff insulator with M5 thread | 25 | M5 | 5 | 4 | 4200 | 2350 | 200 |
| AM1-025-06 | AM1-025-06 STEP file | 25mm high standoff insulator with M6 thread | 25 | M6 | 7 | 8 | 4200 | 2350 | 200 |
| AM1-030-05 | AM1-030-05 STEP file | 30mm high standoff insulator with M5 thread | 30 | M5 | 5 | 4 | 4200 | 2350 | 200 |
| AM1-030-06 | AM1-030-06 STEP file | 30mm high standoff insulator with M6 thread | 30 | M6 | 7 | 8 | 4200 | 2350 | 200 |
| AM1-035-05 | AM1-035-05 STEP file | 35mm high standoff insulator with M5 thread | 35 | M5 | 5 | 4 | 4200 | 2350 | 200 |
| AM1-035-06 | AM1-035-06 STEP file | 35mm high standoff insulator with M6 thread | 35 | M6 | 7 | 8 | 4200 | 2350 | 200 |
* Fixing details: Hole diameter = Standoff thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter.
** Tensile and Cantilever Strength figures are based on tests carried out at normal room temperature, nominal 23 °C.
Our Insulators have ISO M inserts with coarse threaded inserts in accordance with BS 3643-2 – Table 1 and ISO 262.
Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.
| Recognition | Reference / Link | Preferred Name |
|---|---|---|
| UL US Recognised Component | US Certificate: UL-US-E505645 | |
| UL CA Recognised Component | CA Certificate: UL-CA-E505645 | |
| EClass 8.0 | 27-08-10-08 | Insulator, plastic |
| EClass 14.0 | 27-08-10-03 | Bus bar holder (insulator, post insulator) |
| Properties | Value / Measure / Unit |
|---|---|
| Insulator Material | Glass Reinforced Polyamide 6.6 (PA66) |
| Insert Material | Brass |
| Operating Range in Celsius | −40 °C to +130 °C |
| Operating Range in Fahrenheit | −40 °F to +266 °F |
| Flammability | UL 94 V-0 |
| Oxygen Index | 32% |
| Glow Wire | 960 °C |
| Characteristics | Value |
|---|---|
| Maximum Alternating Current Equipment Voltage, Ue | 1000 V |
| Maximum Direct Current Equipment Voltage, Ue | 1500 V |
| Impulse Voltage, Uimp | 12 kV |
The following table provides additional UL Yellow Card information, for the material used in AM1 standoff insulator range, required for assessing the suitability for incorporation into electrical equipment built to North American standards or for use when evaluating unlisted equipment for compliance with North American recognised standards, using methods such as NFPA 791.
| Properties | Value | Test Method |
|---|---|---|
| Hot-wire Ignition (HWI) | PLC 0 | UL 746A |
| High Amp Arc Ignition (HAI) | PLC 1 | UL 746A |
| Comparative Tracking Index (CTI) | PLC 0 | UL 746A |
| UV Exposure & Water Immersion | f1 | UL 746C |
Termate’s AM1 standoff insulator range provides excellent electrical insulation and mechanical strength for a variety of applications. Compact standoff insulators can also be referred to as pillar insulators, insulating posts, bobbin insulators, or busbar isolators.
This standoff insulator range is available in heights from 20 mm to 35 mm and insert sizes of M5 and M6. Technical data is found on the table above which displays heights, thread size and depth, maximum tightening torques, tensile and cantilever strengths, and box quantities available.
- Made from UL 94 V-0 rated, self-extinguishing material
- Halogen Free
- Operating temperature range of −40 °C to +130 °C (−40 °F to +266 °F)
- Insulation voltage of up to 1000 V AC, 1500 V DC
- Equipment voltage of up to 1000 V AC, 1500 V DC
Our standoff insulators are made from a halogen-free glass-reinforced material, which was specifically chosen for its mechanical and electrical insulation properties.
Brass inserts are used due to this alloy’s resistance to corrosion. The injection moulding process, combined with our excellent quality control and inspection procedures, results in a consistent product across every production run.
The AM1 range of standoff insulators is an important product in the Termate catalogue. Prior to entering production, the insulators were subjected to a comprehensive suite of tests that examined their electrical and mechanical performance capabilities.
All tests were conducted within industry standards and with strict quality control measures enforced throughout. This rigorous testing procedure ensures our products are always performing optimally, providing customers with reliable and high-quality insulation solutions. We take pride in providing our customers with the highest quality of products, ensuring all safety and performance requirements are met.
AM1 standoff insulators are manufactured from material that meets the requirements for UL 94 V-0. UL 94 being a standard for the safety of flammability of plastic materials for parts in devices and appliances released by the Underwriters Laboratories.
Our complete Standoff insulator range are UL Recognised Components, more information can be found at UL Product.
Our standoff insulators are suitable for assemblies up to 1000 V AC or up to 1500 V DC. These insulation supports provide a solution for electrical systems that need the assurance of safe and secure insulation.
In installations which require electrical isolation, they ensure that distance is maintained between two surfaces. This maintains the required level of mechanical strength and electrical insulation needed to safely contain live conductors, such as busbars.
Usual installations are within:
- Battery Energy Storage Systems
- Electrical panel boards
- Control panels
- Switchboards
- EV power trains
- Power factor correction
- Distribution boards
- Drives, inverters and converters
These electrical installations can be found in a wide range of sectors including power distribution, rail (rolling stock & trackside), renewable energy, UPS (temporary and emergency power), and data centre power distribution.
AM2
The below table shows the AM2 range of Termate standoff insulators.
The complete AM2 range is suitable for applications with an AC Equipment Voltage Ue up to 1000 V or DC Equipment Voltage Ue up to 1500 V.
The technical data provided in the table below provides information necessary for product selection and technical assessment in line with IEC and UL product standards.
We hold excellent stock of all of our products and will be happy to provide you a quotation for your requirements, please use our contact us page or email our customer support team.

| Part Number | 3D Model | Description | Height [H] (mm) | Thread Size* [M] | Thread Depth [D] (mm) | Maximum Tightening Torque (N·m) | Tensile Strength** (N) | Cantilever Strength** (N) | Box Qty. |
|---|---|---|---|---|---|---|---|---|---|
| AM2-025-06 | AM2-025-06 STEP file | 25mm high standoff insulator with M6 thread | 25 | M6 | 7 | 11 | 9500 | 5500 | 120 |
| AM2-030-06 | AM2-030-06 STEP file | 30mm high standoff insulator with M6 thread | 30 | M6 | 7 | 11 | 9500 | 5200 | 120 |
| AM2-030-08 | AM2-030-08 STEP file | 30mm high standoff insulator with M8 thread | 30 | M8 | 9 | 28 | 12500 | 7300 | 120 |
| AM2-035-06 | AM2-035-06 STEP file | 35mm high standoff insulator with M6 thread | 35 | M6 | 7 | 11 | 9500 | 4900 | 120 |
| AM2-035-08 | AM2-035-08 STEP file | 35mm high standoff insulator with M8 thread | 35 | M8 | 9 | 28 | 12800 | 6900 | 120 |
| AM2-040-06 | AM2-040-06 STEP file | 40mm high standoff insulator with M6 thread | 40 | M6 | 7 | 11 | 9500 | 4700 | 60 |
| AM2-040-08 | AM2-040-08 STEP file | 40mm high standoff insulator with M8 thread | 40 | M8 | 11 | 28 | 13000 | 6600 | 60 |
| AM2-050-06 | AM2-050-06 STEP file | 50mm high standoff insulator with M6 thread | 50 | M6 | 7 | 11 | 9600 | 4100 | 60 |
| AM2-050-08 | AM2-050-08 STEP file | 50mm high standoff insulator with M8 thread | 50 | M8 | 11 | 28 | 13600 | 5800 | 60 |
| AM2-060-06 | AM2-060-06 STEP file | 60mm high standoff insulator with M6 thread | 60 | M6 | 7 | 11 | 9700 | 3600 | 50 |
| AM2-060-08 | AM2-060-08 STEP file | 60mm high standoff insulator with M8 thread | 60 | M8 | 11 | 28 | 14100 | 5100 | 50 |
| AM2-080-06 | AM2-080-06 STEP file | 80mm high standoff insulator with M6 thread | 80 | M6 | 7 | 11 | 9800 | 2500 | 40 |
| AM2-080-08 | AM2-080-08 STEP file | 80mm high standoff insulator with M8 thread | 80 | M8 | 11 | 28 | 15100 | 3600 | 40 |
| AM2-100-06 | AM2-100-06 STEP file | 100mm high standoff insulator with M6 thread | 100 | M6 | 7 | 11 | 9900 | 1400 | 30 |
| AM2-100-08 | AM2-100-08 STEP file | 100mm high standoff insulator with M8 thread | 100 | M8 | 11 | 28 | 16100 | 2200 | 30 |
* Fixing details: Hole diameter = Standoff thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter.
** Tensile and Cantilever Strength figures are based on tests carried out at normal room temperature, nominal 23 °C.
Our Insulators have ISO M inserts with coarse threaded inserts in accordance with BS 3643-2 – Table 1 and ISO 262
Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.
| Recognition | Reference / Link | Preferred Name |
|---|---|---|
| UL US Recognised Component | US Certificate: UL-US-E505645 | |
| UL CA Recognised Component | CA Certificate: UL-CA-E505645 | |
| EClass 8.0 | 27-08-10-08 | Insulator, plastic |
| EClass 14.0 | 27-08-10-03 | Bus bar holder (insulator, post insulator) |
| Properties | Value / Measure / Unit |
|---|---|
| Insulator Material | Glass Reinforced Polyamide 6.6 (PA66) |
| Insert Material | Brass |
| Operating Range in Celsius | −40 °C to +130 °C |
| Operating Range in Fahrenheit | −40 °F to +266 °F |
| Flammability | UL 94 V-0 |
| Oxygen Index | 32% |
| Glow Wire | 960 °C |
| Characteristics | Value |
|---|---|
| Maximum Alternating Current Equipment Voltage, Ue | 1000 V |
| Maximum Direct Current Equipment Voltage, Ue | 1500 V |
| Impulse Voltage, Uimp | 12 kV |
The following table provides additional UL Yellow Card information, for the material used in AM2 standoff insulator range, required for assessing the suitability for incorporation into electrical equipment built to North American standards or for use when evaluating unlisted equipment for compliance with North American recognised standards, using methods such as NFPA 791.
| Properties | Value | Test Method |
|---|---|---|
| Hot-wire Ignition (HWI) | PLC 0 | UL 746A |
| High Amp Arc Ignition (HAI) | PLC 1 | UL 746A |
| Comparative Tracking Index (CTI) | PLC 0 | UL 746A |
| UV Exposure & Water Immersion | f1 | UL 746C |
Termate’s AM2 standoff insulator range provides excellent electrical insulation and mechanical strength for a variety of applications. Standoff insulators can also be referred to as post insulators, egg insulators, bobbin insulators, or busbar isolators.
This standoff insulator range is available in heights from 25 mm to 100 mm and insert sizes of M6 and M8. Technical data is found on the table above which displays heights, thread size and depth, maximum tightening torques, tensile and cantilever strengths, and box quantities available.
- Made from UL 94 V-0 rated, self-extinguishing material
- Halogen Free
- Operating temperature range of −40 °C to +130 °C
- Insulation voltage of up to 1000 V AC, 1500 V DC
- Equipment voltage of up to 1000 V AC, 1500 V DC
- UL Recognised Component; file number E505645
Our standoff insulators are made from a halogen-free glass-reinforced material, which was specifically chosen for its mechanical and electrical insulation properties.
Brass inserts are used due to this alloy’s resistance to corrosion. The injection moulding process, combined with our excellent quality control and inspection procedures, results in a consistent product across every production run.
Termate can carry out rigorous and appropriate testing of your products or we can perform testing on our own products as required.
The AM2 range of standoff insulators have undergone extensive testing to ensure their electrical and mechanical capabilities.
AM2 standoff insulators meet the requirements for UL 94 V-0. UL 94 being a standard for the safety of flammability of plastic materials for parts in devices and appliances released by the Underwriters Laboratories.
The insulating stand off range is also fully compliant with the applicable clauses within the international standard for low-voltage switchgear and controlgear assemblies, IEC 61439.
Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.
Our standoff insulators are suitable for assemblies up to 1000 V AC or up to 1500 V DC. They are intended to safely and securely support and insulate busbars and other live conductors by maintaining a distance between two surfaces. In these types of installations, the electrical insulation and the mechanical strength of the support are paramount. Usual installations are within:
- Battery Energy Storage Systems
- Electrical panel boards
- Control panels
- Switchboards
- EV power trains
- Power factor correction
- Distribution boards
- Generators
- Switchgear
- Controlgear
- Drives, inverters and converters
These electrical installations can be found in a wide range of sectors including power distribution, rail (rolling stock & trackside), renewable energy, UPS (temporary and emergency power), and data centre power distribution.
At Termate, we have been designing and manufacturing electrical insulating parts and components, such as our standoff insulators, from our Nottingham UK based factory for over 60 years. Quality is ensured on every product we produce. Our knowledge and experience of the raw materials used, the performance requirements, and the application of our products allow us to provide products that are safe and fit for purpose.
AM4
The below table shows the AM4 range of Termate standoff insulators.
The complete AM4 range is suitable for applications with an AC Equipment Voltage Ue up to 1000 V or DC Equipment Voltage Ue up to 1500 V.
The technical data provided in the table below provides information necessary for product selection and technical assessment in line with IEC and UL product standards.
We hold excellent stock of all of our products and will be happy to provide you a quotation for your requirements, please use our contact us page or email our customer support team.

| Part Number | 3D Model | Description | Height [H] (mm) | Thread Size* [M] | Thread Depth [D] (mm) | Maximum Tightening Torque (N·m) | Tensile Strength** (N) | Cantilever Strength** (N) | Box Qty. |
|---|---|---|---|---|---|---|---|---|---|
| AM4-030-06 | AM4-030-06 STEP file | 30mm high standoff insulator with M6 thread | 30 | M6 | 7 | 11 | 12300 | 6400 | 60 |
| AM4-030-08 | AM4-030-08 STEP file | 30mm high standoff insulator with M8 thread | 30 | M8 | 9 | 28 | 15500 | 9300 | 60 |
| AM4-035-06 | AM4-035-06 STEP file | 35mm high standoff insulator with M6 thread | 35 | M6 | 7 | 11 | 12300 | 6000 | 60 |
| AM4-035-08 | AM4-035-08 STEP file | 35mm high standoff insulator with M8 thread | 35 | M8 | 9 | 28 | 15900 | 8800 | 60 |
| AM4-035-10 | AM4-035-10 STEP file | 35mm high standoff insulator with M10 thread | 35 | M10 | 10 | 55 | 19000 | 12400 | 60 |
| AM4-040-06 | AM4-040-06 STEP file | 40mm high standoff insulator with M6 thread | 40 | M6 | 7 | 11 | 12200 | 5500 | 50 |
| AM4-040-08 | AM4-040-08 STEP file | 40mm high standoff insulator with M8 thread | 40 | M8 | 11 | 28 | 16300 | 8400 | 50 |
| AM4-040-10 | AM4-040-10 STEP file | 40mm high standoff insulator with M10 thread | 40 | M10 | 10 | 55 | 19500 | 11800 | 50 |
| AM4-045-06 | AM4-045-06 STEP file | 45mm high standoff insulator with M6 thread | 45 | M6 | 7 | 11 | 12200 | 5000 | 50 |
| AM4-045-08 | AM4-045-08 STEP file | 45mm high standoff insulator with M8 thread | 45 | M8 | 11 | 28 | 16700 | 7900 | 50 |
| AM4-045-10 | AM4-045-10 STEP file | 45mm high standoff insulator with M10 thread | 45 | M10 | 16 | 55 | 20000 | 11200 | 50 |
| AM4-050-06 | AM4-050-06 STEP file | 50mm high standoff insulator with M6 thread | 50 | M6 | 7 | 11 | 12200 | 4600 | 25 |
| AM4-050-08 | AM4-050-08 STEP file | 50mm high standoff insulator with M8 thread | 50 | M8 | 11 | 28 | 17100 | 7400 | 25 |
| AM4-050-10 | AM4-050-10 STEP file | 50mm high standoff insulator with M10 thread | 50 | M10 | 16 | 55 | 20500 | 10600 | 25 |
| AM4-050-12 | AM4-050-12 STEP file | 50mm high standoff insulator with M12 thread | 50 | M12 | 16 | 95 | 26600 | 14000 | 25 |
| AM4-060-08 | AM4-060-08 STEP file | 60mm high standoff insulator with M8 thread | 60 | M8 | 11 | 28 | 17900 | 6500 | 25 |
| AM4-060-10 | AM4-060-10 STEP file | 60mm high standoff insulator with M10 thread | 60 | M10 | 16 | 55 | 21400 | 9500 | 25 |
| AM4-060-12 | AM4-060-12 STEP file | 60mm high standoff insulator with M12 thread | 60 | M12 | 16 | 95 | 27100 | 11400 | 25 |
* Fixing details: Hole diameter = Standoff thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter
** Tensile and Cantilever Strength figures are based on tests carried out at normal room temperature, nominal 23 °C
Our Insulators have ISO M inserts with coarse threaded inserts in accordance with BS 3643-2 – Table 1 and ISO 262
Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.
| Recognition | Reference / Link | Preferred name |
|---|---|---|
| UL US Recognised Component | US Certificate: UL-US-E505645 | |
| UL CA Recognised Component | CA Certificate: UL-CA-E505645 | |
| EClass 8.0 | 27-08-10-08 | Insulator, plastic |
| EClass 14.0 | 27-08-10-03 | Bus bar holder (insulator, post insulator) |
| Properties | Value / Measure / Unit |
|---|---|
| Insulator Material | Glass Reinforced Polyamide 6.6 (PA66) |
| Insert Material | Brass |
| Operating Range in Celsius | This material operates in a wide temperature range: −40 °C to +130 °C |
| Operating Range in Fahrenheit | This material operates in a wide temperature range: −40 °F to +266 °F |
| Flammability | UL 94 V-0 |
| Oxygen Index | 32% |
| Glow Wire | 960 °C |
| Characteristics | Value |
|---|---|
| Maximum Alternating Current Equipment Voltage, Ue | 1000 V |
| Maximum Direct Current Equipment Voltage, Ue | 1500 V |
| Impulse Voltage, Uimp | 12 kV |
The following table provides additional UL Yellow Card information, for the material used in AM4 standoff insulator range, required for assessing the suitability for incorporation into electrical equipment built to North American standards or for use when evaluating unlisted equipment for compliance with North American recognised standards, using methods such as NFPA 791.
| Properties | Value | Test Method |
|---|---|---|
| Hot-wire Ignition (HWI) | PLC 0 | UL 746A |
| High Amp Arc Ignition (HAI) | PLC 1 | UL 746A |
| Comparative Tracking Index (CTI) | PLC 0 | UL 746A |
| UV Exposure & Water Immersion | f1 | UL 746C |
Suitable for a variety of assemblies, the AM4 standoff insulator range supplies excellent mechanical strength and electrical insulation.
Post insulators, egg insulators, bobbin insulators, and busbar isolators are all terms used to describe standoff insulators.
Our AM4 insulating standoffs come in different heights from 30 mm to 60 mm, as well as insert sizes of M6 to M12. Heights, thread depths and sizes, maximum tightening torques, cantilever and tensile strengths, and box quantities are all listed in the table above.
The AM4 insulators have the following properties:
- Halogen Free
- Equipment voltage of up to 1000 V AC, 1500 V DC
- Insulation voltage of up to 1000 V AC, 1500 V DC
- Operating temperature ranging from −40 °C to +130 °C
- UL Recognised Component; file number E505645
- Made from UL 94 V-0 rated, self-extinguishing material
Termate AM4 standoff insulators are manufactured from halogen free glass-reinforced polyamide 6.6 material and contain precision threaded brass alloy inserts for greater corrosion resistance.
The injection moulding process we use to manufacture our electrical insulating parts improves overall product quality and design accuracy.
Product testing is critical for any component that will be used in an electrical or mechanical system.
Professional, thorough, and independent testing has been performed on the AM4 standoff insulator range to assure efficacy when installed correctly in their intended assembly.
Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.
One of the most widely used tests for determining the ability of plastic parts to self-extinguish after the heat source has been removed is UL 94. All Termate standoffs meet V-0 requirements for the UL 94 test standard.
Our standoff insulators have undergone comprehensive testing, including cantilever, torque, and tensile tests, to give you peace of mind that they will fulfil specified ratings when fitted appropriately.
These standoff insulators are designed to hold live busbars and other active conductors as an insulating support, safely and securely, by keeping a gap between two surfaces and is appropriate for assemblies up to 1000 V AC & 1500 V DC.
The electrical insulation and mechanical strength of the support are critical in these types of systems.
A list of some of the most common applications for our insulators include:
- Battery Energy Storage Systems
- Electrical panel boards
- Control panels
- Switchboards
- EV power trains
- Power factor correction
- Distribution boards
- Generators
- Switchgear
- Controlgear
- Drives, inverters and converters
Power distribution, rail (rolling stock & trackside), renewable energy, UPS (temporary and emergency power), and data centre power distribution are all examples of sectors where these electrical installations and assemblies are used.
For over 60 years, Termate has designed and manufactured electrical insulating parts and components at our UK-based site. Every insulating plastic product we make is of the highest quality so that we can provide electrical insulating solutions that are safe and suitable for purpose. By becoming a part of our portfolio of trusted customers, we can provide time-effective results for your projects.
AM6
The below table shows the AM6 range of Termate standoff insulators.
The complete AM6 range is suitable for applications with an AC Equipment Voltage Ue up to 1000 V or DC Equipment Voltage Ue up to 1500 V.
The technical data provided in the table below provides information necessary for product selection and technical assessment in line with IEC and UL product standards.
We hold excellent stock of all of our products and will be happy to provide you a quotation for your requirements, please use our contact us page or email our customer support team.

| Part Number | 3D Model | Description | Height [H] (mm) | Thread Size* [M] | Thread Depth [D] (mm) | Maximum Tightening Torque (N·m) | Tensile Strength** (N) | Cantilever Strength** (N) | Box Qty. |
|---|---|---|---|---|---|---|---|---|---|
| AM6-060-08 | AM6-060-08 STEP file | 60mm high standoff insulator with M8 thread | 60 | M8 | 11 | 28 | 18100 | 8600 | 20 |
| AM6-060-10 | AM6-060-10 STEP file | 60mm high standoff insulator with M10 thread | 60 | M10 | 16 | 55 | 24500 | 12600 | 20 |
| AM6-060-10-12 | AM6-060-10-12 STEP file | 60mm high standoff insulator with an M10 and M12 thread either end | 60 | M10 + M12 | 16 | 55 | 24500 | 12600 | 20 |
| AM6-060-12 | AM6-060-12 STEP file | 60mm high standoff insulator with M12 thread | 60 | M12 | 16 | 95 | 30300 | 17000 | 20 |
| AM6-060-16 | AM6-060-16 STEP file | 60mm high standoff insulator with M16 thread | 60 | M16 | 22 | 130 | 41800 | 24500 | 20 |
| AM6-070-08 | AM6-070-08 STEP file | 70mm high standoff insulator with M8 thread | 70 | M8 | 11 | 28 | 16900 | 7900 | 20 |
| AM6-070-10 | AM6-070-10 STEP file | 70mm high standoff insulator with M10 thread | 70 | M10 | 16 | 55 | 23400 | 11300 | 20 |
| AM6-070-12 | AM6-070-12 STEP file | 70mm high standoff insulator with M12 thread | 70 | M12 | 16 | 95 | 28300 | 14900 | 20 |
| AM6-070-16 | AM6-070-16 STEP file | 70mm high standoff insulator with M16 thread | 70 | M16 | 22 | 130 | 31500 | 21400 | 20 |
| AM6-100-08 | AM6-100-08 STEP file | 100mm high standoff insulator with M8 thread | 100 | M8 | 11 | 28 | 13500 | 5700 | 10 |
| AM6-100-10 | AM6-100-10 STEP file | 100mm high standoff insulator with M10 thread | 100 | M10 | 16 | 55 | 20300 | 7300 | 10 |
| AM6-100-12 | AM6-100-12 STEP file | 100mm high standoff insulator with M12 thread | 100 | M12 | 16 | 95 | 22200 | 8700 | 10 |
| AM6-100-16 | AM6-100-16 STEP file | 100mm high standoff insulator with M16 thread | 100 | M16 | 22 | 130 | 35300 | 12400 | 10 |
* Fixing details: Hole diameter = Standoff thread size [M]+1 mm. e.g. M6 Thread = 7 mm hole diameter
** Tensile and Cantilever Strength figures are based on tests carried out at normal room temperature, nominal 23 °C.
Our Insulators have ISO M inserts with coarse threaded inserts in accordance with BS 3643-2 – Table 1 and ISO 262
Our metric insulators can be converted into Male/Male or Female/Male versions by fitting studs from our Grub Screw Pack.
| Recognition | Reference / Link | Preferred name |
|---|---|---|
| UL US Recognised Component | US Certificate: UL-US-E505645 | |
| UL CA Recognised Component | CA Certificate: UL-CA-E505645 | |
| EClass 8.0 | 27-08-10-08 | Insulator, plastic |
| EClass 14.0 | 27-08-10-03 | Bus bar holder (insulator, post insulator) |
| Properties | Value / Measure / Unit |
|---|---|
| Insulator Material | Glass Reinforced Polyamide 6.6 (PA66) |
| Insert Material | Brass |
| Operating Range in Celsius | This material operates in a wide temperature range: −40 °C to +130 °C |
| Operating Range in Fahrenheit | This material operates in a wide temperature range: −40 °F to +266 °F |
| Flammability | UL 94 V-0 |
| Oxygen Index | 32% |
| Glow Wire | 960 °C |
| Characteristics | Value |
|---|---|
| Maximum Alternating Current Equipment Voltage, Ue | 1000 V |
| Maximum Direct Current Equipment Voltage, Ue | 1500 V |
| Impulse Voltage, Uimp | 12 kV |
The following table provides additional UL Yellow Card information, for the material used in AM6 standoff insulator range, required for assessing the suitability for incorporation into electrical equipment built to North American standards or for use when evaluating unlisted equipment for compliance with North American recognised standards, using methods such as NFPA 791.
| Properties | Value | Test Method |
|---|---|---|
| Hot-wire Ignition (HWI) | PLC 0 | UL 746A |
| High Amp Arc Ignition (HAI) | PLC 1 | UL 746A |
| Comparative Tracking Index (CTI) | PLC 0 | UL 746A |
| UV Exposure & Water Immersion | f1 | UL 746C |
The AM6 standoff insulator range provides excellent mechanical strength and electrical insulation, making it suitable for a wide range of application. Post insulators, egg insulators, bobbin insulators, and busbar isolators are also other names for standoff insulators.
Termate AM6 standoff insulators are available in thread sizes of M8 to M16, including heights ranging from 60 mm to 100 mm. The table above list the heights, thread depths and diameters, cantilever and tensile strengths, maximum tightening torques, and box quantities.
They also possess the following characteristics:
- Halogen Free
- Relative Thermal Index ranging from −40 °C to +130 °C
- Equipment voltage of up to 1000 V AC, 1500 V DC
- Insulation voltage of up to 1000 V AC, 1500 V DC
- Made from UL 94 V-0 rated, self-extinguishing material
- UL Recognised Component; file number E505645
Termate AM6 standoff insulators are made from a halogen-free glass-reinforced material with threaded brass inserts for better corrosion resistance.
The injection moulding method, which we utilise to make the bulk of our power distribution parts, including our standoff insulators, enhances overall product quality and allows for close dimensional tolerances.
Product testing is critical for any component that will be used in an electrical or mechanical system.
Professional, thorough, and independent testing has been performed on the AM6 standoff insulator range to assure efficacy when installed correctly in their intended assembly.
Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.
One of the most widely used tests for determining the ability of plastic parts to self-extinguish after the heat source has been removed is UL 94. All Termate standoffs meet V-0 requirements for the UL 94 test standard.
Our standoff insulators have undergone comprehensive testing, including cantilever, torque, and tensile tests, to give you peace of mind that they will fulfil specified ratings when fitted appropriately.
Any component that will be used in an electrical or mechanical system must be thoroughly tested. The AM6 standoff insulator has undergone extensive, rigorous, and independent testing to ensure functionality when installed correctly in its intended application.
Our Standoff insulator range is a UL Recognised Component, more information can be found at UL Product IQ.
UL 94 is one of the most widely employed methods of evaluating the flammability and self-extinguishing ability of plastic products.
The AM6 insulator range is manufactured from material meeting the UL 94 V-0 flammability rating for plastics.
Termate insulators have been thoroughly tested, including cantilever, torque, and tensile tests, to help ensure that they meet the specific ratings when installed correctly.
AM6 standoff insulators are designed to safely and securely support and insulate busbars and other active conductors by maintaining a space between two surfaces.
They are suitable for applications up to 1000 V AC and 1500 V DC. In these types of systems, the support’s electrical insulation and mechanical strength are crucial. The following are examples of common installations:
- Battery Energy Storage Systems
- Electrical panel boards
- Control panels
- Switchboards
- EV power trains
- Power factor correction
- Distribution boards
- Generators
- Switchgear
- Controlgear
- Drives, inverters and converters.
These electrical installations are utilised in a variety of industries, including power distribution, rail (rolling stock and trackside), UPS (temporary and emergency power), data centre power distribution, and renewable energy.
For more than 60 years, Termate has been expertly manufacturing specialised insulating products and components in Nottingham, UK.
We are committed to using our engineering knowledge to create and produce top-of-the-line parts, so you can be confident in the quality of our goods. For our customers, our in-house product development team is continually working to improve existing parts and develop new, unique components.
Termate is committed to the highest standard of customer focus and we have made every effort to maintain the accuracy and completeness of the information provided in this data.
Where improvements to our products affect their installation and usage we endeavour to contact any customers who may be affected.
Warranty as stated in our Terms and Conditions of Trading is void if any modification is made to the warranted product.